FAA20 Embedded NEXCOM Vocoder
Board Manual
This manual has been prepared for the Federal Aviation Administration.
FA100-00107 (March 2004) Rev 1.0.0 Page 48
7.2.2 Nibble Tools
There are three types of NIB test and integration tools:
Nibble Data
COM3 Monitor
BIT Command
For the nibble data interface, the FAA20 supports the generation of a
known nibble test pattern when TEST NTX is enabled. The first voice
nibble is set to 0xF and the remaining nibble values are an incrementing
sequence beginning with 0x1. In addition, the FAA20 also can print the
received nibble frame (see DUMP NRX). Finally, the nibble data interface
supports an external data loopback, e.g. LOOP NIB.
The COM3 monitor is used to troubleshoot the COM3 virtual terminal
interface. When TEST COM3 is enabled, the FAA20 prints all COM3 traffic
to the COM2 port.
The BIT command can be used to manually toggle IO signal conductors;
however, the TEST operational mode must first be enabled to disable
automatic software control.
7.2.3 PCM Tools
The most useful PCM test tool is the external data loopback, i.e LOOP
PCM. In addition, the FAA20 also supports the transmission of an
incrementing data pattern (TEST PCMO).